Molded Case Circuit Breaker
RDM1e molded case circuit breaker is suitable for short circuit and overload protection for electric circuit of AC 690V, 50/60Hz, with rated current from 6 to 800A. It is commonly used in the circuit for infrequent breaking and starting of the motor. It conforms to IEC60947-2.
People Group is one of the professional molded case circuit breaker manufacturers and suppliers in China. Our products include circuit breakers, distribution box, relay, master switch, and so on. In order to achieve customer satisfaction, environmental protection, and minimize risk to employees, etc. we have earned ISO 9001:2000, ISO 14001:2004 and OHSAS18001:1999 certifications.
If you are looking for any of products, please contact us directly. We are ready to help you.
Specification
| Model |
Rated current (A) |
Rated setting current (A) |
Rated Insulation voltage(V) |
Rated operating voltage(V) |
Arcing distance (mm) |
Ultimate short circuit breaking capacity(kA) |
Service short circuit breaking capacity(kA) |
| RDM1-100M |
32 |
16,20, 25,32 |
800 |
380/ 400/ 415 |
≤50 |
50 |
25 |
| 63 |
32,36,40,45, 50,55,60,63 |
| RDM1-100H |
85 |
45 |
| 100 |
63,65,70,75,80, 85,90,95,100, |
| RDM1-225M |
225 |
100,125,140,160, 180,200,225 |
≤50 |
50 |
25 |
| RDM1-225H |
85 |
50 |
| RDM1-400M |
400 |
200,225,250,280, 315,350,400 |
≤50 |
65 |
32 |
| RDM1-400H |
100 |
55 |
| RDM1-630M |
630 |
400,420,440,460,480, 500,530,560,600,630 |
≤100 |
65 |
32 |
| RDM1-630H |
100 |
55 |
| RDM1-800M |
800 |
630,640,660,680,700, 720,740,760,780,800 |
≤100 |
65 |
42 |
| RDM1-800H |
100 |
60 |
Other Products
-

- Analog Panel MeterSpecification: 0.5A, 1A, 1.5A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A, 80A, and 100A. If the current is above 100A, the AC ammeter can be used to measure the secondary ...
-

- Digital Panel MeterAccuracy: 0.5% ±2 digits
Measuring range: 0-5A AC, for the current over 5A, the digital AC meter can be used in combination with AC current transformer.
Voltage Testing: Over 2000V
-

- Kilowatt Hour MeterRated Voltage (V): Two-
phase three-wire 3*100V 3*220V 3*380V or 3*400V Three-phase four-wire 3*220V/380V 3*230V/400V 3*240V/415V or 3*57.5V/100V
-

- Temperature ControllerInput signal: Universal input: Thermocouple RTD Voltage, Current input
Output signal: SSR, Current output DC 0~10mA, 4~20mA, Voltage output DC0~5V, 1~5V, Voltage ...
-

- Dry Type TransformerMax ambient temperature: +40℃
Min ambient temperature: -5℃(the lowest storage temperature: -30℃)
Daily mean temperature:
< 30℃ annual mean ...
-

- Three Phase Oil Immersed Power TransformerCompared with old type S7, S9 three phase oil immersed power transformer has advantages that its no-load loss decreases 10.25% ...
-

- Combination Transformer SubstationIlluminating devices are installed inside the low voltage and high voltage cubicles and transformer cubicle, which makes supervision ...
-

- Voltage Transformer RZL12, JDZL10-3,6,10A(B)Power factor of load: COSφ=0.8(lagging)
Given below are more detailed specifications of our voltage transformer.
The voltage transformer is ...