Molded Case Circuit Breaker

Home » Products » Circuit Breakers » Molded Case Circuit Breaker » RDM1e Molded Case Circuit Breaker
Molded Case Circuit Breaker

RDM1e molded case circuit breaker is suitable for short circuit and overload protection for electric circuit of AC 690V, 50/60Hz, with rated current from 6 to 800A. It is commonly used in the circuit for infrequent breaking and starting of the motor. It conforms to IEC60947-2.

People Group is one of the professional molded case circuit breaker manufacturers and suppliers in China. Our products include circuit breakers, distribution box, relay, master switch, and so on. In order to achieve customer satisfaction, environmental protection, and minimize risk to employees, etc. we have earned ISO 9001:2000, ISO 14001:2004 and OHSAS18001:1999 certifications.
If you are looking for any of products, please contact us directly. We are ready to help you.

Specification

Model Rated current (A) Rated setting current (A) Rated Insulation voltage(V) Rated operating voltage(V) Arcing distance (mm) Ultimate short circuit breaking capacity(kA) Service short circuit breaking capacity(kA)
RDM1-100M 32 16,20, 25,32 800 380/ 400/ 415 ≤50 50 25
63 32,36,40,45, 50,55,60,63
RDM1-100H 85 45
100 63,65,70,75,80, 85,90,95,100,
RDM1-225M 225 100,125,140,160, 180,200,225 ≤50 50 25
RDM1-225H 85 50
RDM1-400M 400 200,225,250,280, 315,350,400 ≤50 65 32
RDM1-400H 100 55
RDM1-630M 630 400,420,440,460,480, 500,530,560,600,630 ≤100 65 32
RDM1-630H 100 55
RDM1-800M 800 630,640,660,680,700, 720,740,760,780,800 ≤100 65 42
RDM1-800H 100 60
Feedback Form
Other Products
    1. Analog Panel MeterSpecification: 0.5A, 1A, 1.5A, 3A, 5A, 7.5A, 10A, 15A, 20A, 25A, 30A, 40A, 50A, 60A, 80A, and 100A. If the current is above 100A, the AC ammeter can be used to measure the secondary ...
    1. Digital Panel MeterAccuracy: 0.5% ±2 digits
      Measuring range: 0-5A AC, for the current over 5A, the digital AC meter can be used in combination with AC current transformer.
      Voltage Testing: Over 2000V
    1. Kilowatt Hour MeterRated Voltage (V): Two-
      phase three-wire 3*100V 3*220V 3*380V or 3*400V Three-phase four-wire 3*220V/380V 3*230V/400V 3*240V/415V or 3*57.5V/100V
    1. Temperature ControllerInput signal: Universal input: Thermocouple RTD Voltage, Current input
      Output signal: SSR, Current output DC 0~10mA, 4~20mA, Voltage output DC0~5V, 1~5V, Voltage ...
    1. Dry Type TransformerMax ambient temperature: +40℃
      Min ambient temperature: -5℃(the lowest storage temperature: -30℃)
      Daily mean temperature:
      < 30℃ annual mean ...
    1. Three Phase Oil Immersed Power TransformerCompared with old type S7, S9 three phase oil immersed power transformer has advantages that its no-load loss decreases 10.25% ...
    1. Combination Transformer SubstationIlluminating devices are installed inside the low voltage and high voltage cubicles and transformer cubicle, which makes supervision ...
    1. Voltage Transformer RZL12, JDZL10-3,6,10A(B)Power factor of load: COSφ=0.8(lagging)
      Given below are more detailed specifications of our voltage transformer.